11 April 2007 Elastic and magneto-elastic modeling of Galfenol nanowires
Author Affiliations +
Abstract
This paper presents a magneto-elastic model developed by coupling a finite element elastic and magnetic formulations with an energy based probabilistic magnetostrictive model. Unidirectional coupled model is presented first for both sensor and actuator applications and then a fully coupled bidirectional model is developed. The unidirectional sensor model was validated against experimental results for a 1.58 mm diameter and 32.74 mm long Galfenol cantilever beam. The model was further used to investigate the response of Galfenol nanowire array that will be used in a nanowire acoustic sensor. Model predictions suggest that differences in the phase of bending motion of nanowires in an array will not produce a significant effect on the magnetic response of the array. It also predicts that the response of a single nanowire can be measured by a magnetic sensor with active measurement area much larger than the nanowire dimensions.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Chaitanya Mudivarthi, Chaitanya Mudivarthi, Patrick Downey, Patrick Downey, Alison B. Flatau, Alison B. Flatau, } "Elastic and magneto-elastic modeling of Galfenol nanowires", Proc. SPIE 6528, Nanosensors, Microsensors, and Biosensors and Systems 2007, 652803 (11 April 2007); doi: 10.1117/12.715296; https://doi.org/10.1117/12.715296