Translator Disclaimer
30 April 2007 Spectral radiant emission of dynamic resistive arrays
Author Affiliations +
Abstract
A persistent question in the infrared scene projection community has been the spectral characteristics of resistive array emission. This paper describes the results of a comprehensive study performed on two resistive array technologies; the Nuclear Optical Dynamic Display System (NODDS) and the Santa Barbara Infrared (SBIR) Large Format Resistive Array (LFRA) product lines. A Fourier Transform Infrared (FTIR) spectral radiometer is used to measure the spectral radiant emission of both resistive array technologies at multiple drive levels and substrate temperatures. Application of the results to scene projection and cross spectral non-uniformity correction is discussed.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Matthew Brown, Alexander G. Hayes, Kirk Anderson, Jay James, and David C. Harrison "Spectral radiant emission of dynamic resistive arrays", Proc. SPIE 6544, Technologies for Synthetic Environments: Hardware-in-the-Loop Testing XII, 654402 (30 April 2007); https://doi.org/10.1117/12.717871