3 March 2008 Low noise and high resolution microchannel plate
Author Affiliations +
Proceedings Volume 6621, International Symposium on Photoelectronic Detection and Imaging 2007: Photoelectronic Imaging and Detection; 662105 (2008) https://doi.org/10.1117/12.790585
Event: International Symposium on Photoelectronic Detection and Imaging: Technology and Applications 2007, 2007, Beijing, China
Abstract
To improve the Figure of Merit (FOM) and reduce the Equivalent Background Input (EBI) and Fixed-Pattern-Noise (FPN) in image intensifier, NVT (North Night Vision Technology Co., Ltd) has been researching and developing a low noise and high resolution Micro Channel Plate (MCP). The density of dark current of this new MCP is less than 0.5PA/cm2 (when MCP voltage at 1000V). The FPN and scintillation noise are reduced remarkably. Channel diameter is 6 &mgr;m and open area ratio is 60&percent;∼70&percent;. The vacuum bakeout temperature could be as high as 500°C. This new kind of MCP will be extensively used in the supper generation and the third generation image intensifiers.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Shulin Liu, Shulin Liu, Jingsheng Pan, Jingsheng Pan, Guangxu Deng, Guangxu Deng, Detan Su, Detan Su, Zhiqing Xu, Zhiqing Xu, Yanyun Zhang, Yanyun Zhang, } "Low noise and high resolution microchannel plate", Proc. SPIE 6621, International Symposium on Photoelectronic Detection and Imaging 2007: Photoelectronic Imaging and Detection, 662105 (3 March 2008); doi: 10.1117/12.790585; https://doi.org/10.1117/12.790585