Paper
9 January 2008 2-DOF haptic device with DC motors and MR brakes
Jinung An, Dong-Soo Kwon
Author Affiliations +
Proceedings Volume 6794, ICMIT 2007: Mechatronics, MEMS, and Smart Materials; 67941I (2008) https://doi.org/10.1117/12.784403
Event: ICMIT 2007: Mechatronics, MEMS, and Smart Materials, 2007, Gifu, Japan
Abstract
This paper presents the 2-DOF haptic device in which DC motors and MR brakes are equipped. To apply MR brakes to the 2-DOF haptic device, its kinematic requirement is described by Jacobian analysis. Through the analysis, MR brakes can be used to display the damping force in a multi-DOF haptic device when it has the orthogonal Jacobian such as Cartesian manipulator. A five bar linkage type haptic device, which has the nonorthogonal Jacobian, is developed to verify the theoretical effort. Experimental results show that the five bar linkage type can't display the 2 DOF virtual environments due to its kinematic constraints, that is, nonorthogonal Jacobian.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Jinung An and Dong-Soo Kwon "2-DOF haptic device with DC motors and MR brakes", Proc. SPIE 6794, ICMIT 2007: Mechatronics, MEMS, and Smart Materials, 67941I (9 January 2008); https://doi.org/10.1117/12.784403