28 January 2008 Evaluation of characterization methods of printer MTF
Author Affiliations +
Abstract
We explore two recent methods for measuring the Modeling Transfer Function of a printing system12. We investigate the dependency on the amplitude when using the sinusoidal patches of the method proposed in1 and show that for too small amplitudes the measurement of the MTF is not trustworthy. For the method proposed in2 we discuss the underlying theory and in particular the use of a significance test for a statistical analysis. Finally we compare both methods with respect our application - the processing and printing of photographic images.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Albrecht J. Lindner, Albrecht J. Lindner, Nicolas Bonnier, Nicolas Bonnier, Christophe Leynadier, Christophe Leynadier, Francis Schmitt, Francis Schmitt, } "Evaluation of characterization methods of printer MTF", Proc. SPIE 6808, Image Quality and System Performance V, 680806 (28 January 2008); doi: 10.1117/12.764607; https://doi.org/10.1117/12.764607