Paper
12 March 2008 Feasibility of quantitative lung perfusion by 4D CT imaging by a new dynamic-scanning protocol in an animal model
Yang Wang, Jonathan G. Goldin, Fereidoun G. Abtin, Matt Brown, Mike McNitt-Gray
Author Affiliations +
Abstract
The purpose of this study is to test a new dynamic Perfusion-CT imaging protocol in an animal model and investigate the feasibility of quantifying perfusion of lung parenchyma to perform functional analysis from 4D CT image data. A novel perfusion-CT protocol was designed with 25 scanning time points: the first at baseline and 24 scans after a bolus injection of contrast material. Post-contrast CT scanning images were acquired with a high sampling rate before the first blood recirculation and then a relatively low sampling rate until 10 minutes after administrating contrast agent. Lower radiation techniques were used to keep the radiation dose to an acceptable level. 2 Yorkshire swine with pulmonary emboli underwent this perfusion- CT protocol at suspended end inspiration. The software tools were designed to measure the quantitative perfusion parameters (perfusion, permeability, relative blood volume, blood flow, wash-in & wash-out enhancement) of voxel or interesting area of lung. The perfusion values were calculated for further lung functional analysis and presented visually as contrast enhancement maps for the volume being examined. The results show increased CT temporal sampling rate provides the feasibility of quantifying lung function and evaluating the pulmonary emboli. Differences between areas with known perfusion defects and those without perfusion defects were observed. In conclusion, the techniques to calculate the lung perfusion on animal model have potential application in human lung functional analysis such as evaluation of functional effects of pulmonary embolism. With further study, these techniques might be applicable in human lung parenchyma characterization and possibly for lung nodule characterization.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yang Wang, Jonathan G. Goldin, Fereidoun G. Abtin, Matt Brown, and Mike McNitt-Gray "Feasibility of quantitative lung perfusion by 4D CT imaging by a new dynamic-scanning protocol in an animal model", Proc. SPIE 6916, Medical Imaging 2008: Physiology, Function, and Structure from Medical Images, 69161H (12 March 2008); https://doi.org/10.1117/12.772720
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Lung

Computed tomography

Animal model studies

4D CT imaging

Functional analysis

Blood

Data modeling

Back to Top