16 April 2008 High accuracy LADAR scene projector calibration sensor development
Author Affiliations +
Abstract
A sensor system for the characterization of infrared laser radar scene projectors has been developed. Available sensor systems do not provide sufficient range resolution to evaluate the high precision LADAR projector systems developed by the U.S. Army Research, Development and Engineering Command (RDECOM) Aviation and Missile Research, Development and Engineering Center (AMRDEC). With timing precision capability to a fraction of a nanosecond, it can confirm the accuracy of simulated return pulses from a nominal range of up to 6.5 km to a resolution of 4cm. Increased range can be achieved through firmware reconfiguration. Two independent amplitude triggers measure both rise and fall time providing a judgment of pulse shape and allowing estimation of the contained energy. Each return channel can measure up to 32 returns per trigger characterizing each return pulse independently. Currently efforts include extending the capability to 8 channels. This paper outlines the development, testing, capabilities and limitations of this new sensor system.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Hajin J. Kim, Hajin J. Kim, Michael C. Cornell, Michael C. Cornell, Charles B. Naumann, Charles B. Naumann, Mark H. Bowden, Mark H. Bowden, } "High accuracy LADAR scene projector calibration sensor development", Proc. SPIE 6942, Technologies for Synthetic Environments: Hardware-in-the-Loop Testing XIII, 694206 (16 April 2008); doi: 10.1117/12.778352; https://doi.org/10.1117/12.778352