15 April 2008 A new integrated neutron/gamma radioisotope identification device evaluated under mixed radiation fields
Author Affiliations +
Abstract
Hand-Held RadioIsotope Identification Devices (HHRIID) are defined as a new class of portable neutron/gamma radiation detectors with specifications presented in the ANSI Standards N42.33 and N42.34. We have proposed a novel HHRIID design concept which uses a single photosensor to detect light emitted by two optically separated scintillator materials, one optimized for gamma detection and the other optimized for neutron detection. This work describes the performance of a modified charge integration discrimination method developed to test the viability of the new design. The scintillators chosen for the experiment were LYSO and ZnS:Ag/LiF.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Adrian Ivan, Adrian Ivan, Brent A. Clothier, Brent A. Clothier, Daniel B. McDevitt, Daniel B. McDevitt, James Williams, James Williams, } "A new integrated neutron/gamma radioisotope identification device evaluated under mixed radiation fields", Proc. SPIE 6945, Optics and Photonics in Global Homeland Security IV, 694506 (15 April 2008); doi: 10.1117/12.782194; https://doi.org/10.1117/12.782194