Paper
15 July 2008 Flight calibration of the Suzaku XIS using the charge injection technique
Author Affiliations +
Abstract
The X-ray Imaging Spectrometer (XIS) on board the Suzaku satellite is an X-ray CCD camera system that has features of a low background, high quantum efficiency, and good energy resolution in the 0.2 - 12 keV band. Because of the radiation damage, however, the energy resolution of the XIS has been degraded since Suzaku was launched (July 2005). One of the major advantages of the XIS over the other X-ray CCDs in orbit is the provision of a precision charge injection (CI) capability. In order to improve the energy resolution, the precise measurement of charge transfer inefficiency (CTI) is essential. For this purpose, we applied the checker-flag CI, and we were able to measure the CTI of each CCD column. Furthermore, we were able to obtain the pulse height dependency of the CTI. Our precise CTI correction using these results improved the energy resolution from 193 eV to 173 eV in FWHM at 5.9 keV in July 2006 (one year after the launch). The energy resolution can be improved also by reducing the CTI. For this purpose, we applied the spaced-row charge injection (SCI); periodically injected artificial charges work as if they compensate radiation-induced traps and prevent electrons produced by X-rays from being captured by the charge traps. Using this method, the energy resolution improved from 210 eV to 150 eV at 5.9 keV in September 2006, which is close to the resolution just after the launch (145 eV). We report the current in-orbit calibration status of the XIS data using these two techniques. We present the time history of the gain and energy resolution determined from onboard calibration sources (55Fe) and observed calibration objects like E0102-72.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Midori Ozawa, Hideki Uchiyama, Hiroshi Nakajima, Hideyuki Mori, Hironori Matsumoto, Takeshi Go Tsuru, Katsuji Koyama, Masahiro Uchino, Kiyoshi Hayashida, Hiroshi Tsunemi, Hiroshi Murakami, Tadayasu Dotani, Gregory Prigozhin, Steve Kissel, Eric Miller, Beverly LaMarr, and Marshall Bautz "Flight calibration of the Suzaku XIS using the charge injection technique", Proc. SPIE 7011, Space Telescopes and Instrumentation 2008: Ultraviolet to Gamma Ray, 70112B (15 July 2008); https://doi.org/10.1117/12.788258
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

X-rays

Charge-coupled devices

X-ray imaging

Gamma radiation

Satellite imaging

Satellites

RELATED CONTENT

Soft x-ray imager (SXI) onboard ASTRO-H
Proceedings of SPIE (July 18 2016)
Swift: results from the first year of the mission
Proceedings of SPIE (July 26 2006)
X-ray imaging spectrometer (XIS) on board Astro-E2
Proceedings of SPIE (March 11 2003)
UV, soft x ray, and gamma ray high resolution imaging...
Proceedings of SPIE (October 31 1996)
Current status of Suzaku and its early results
Proceedings of SPIE (June 15 2006)
The operation and evolution of the swift x-ray telescope
Proceedings of SPIE (September 13 2007)

Back to Top