29 August 2008 Aspherical optics design for minimal spherical aberration in vision correction of human eyes
Author Affiliations +
Abstract
Using raytracing method (ZEMAX program), the reduction of SA of the whole human eye may be reduced via the combined effects of asphericity (Q) and the ratio of the front and back surface of an IOL. The overall SA for best image quality may be defined by Q* when the image position off axis is reduced to that of the paraxial. Our calculations show the following general features: (1) For a give Q value, the influence on the SA is proportional to the surface power; (2) for minimal whole eye SA, negative Q is needed in IOL; (3) for a given IOL power, the Q* is smaller when the front surface has a smaller power. All above features derived from numerical raytracing method are consistent with analytic formulas.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Min-shan Jiang, Min-shan Jiang, J. T. Lin, J. T. Lin, Chuan-qing Zhou, Chuan-qing Zhou, Qiu-shi Ren, Qiu-shi Ren, } "Aspherical optics design for minimal spherical aberration in vision correction of human eyes", Proc. SPIE 7060, Current Developments in Lens Design and Optical Engineering IX, 706013 (29 August 2008); doi: 10.1117/12.799012; https://doi.org/10.1117/12.799012