Paper
23 February 2009 An optical tomography method that accounts for a titled chest-wall in breast imaging
Author Affiliations +
Abstract
The chest-wall underneath the breast tissue distorts the diffused near infra-red light measured at distant source-detector pairs. Common image reconstruction method consider the media as homogeneous and applying the semi-infinite model. In this paper, we have compared the performance of our two-layer model with semi-infinite model by simulation and a clinical case. The results show that when the chest wall has significant effect on the measurement data, a benign lesion with low absorption can be misled as a malignant case with high absorption by using semi-infinite model. We have also shown the influence of mismatch geometry of breast tissue and chest-wall at lesion and reference sides on the reconstructed image and a correction method has been introduced to reduce these effects. With the assistance of two orthogonal co-registered ultrasounds, the geometry of the breast tissue and chest wall interface can be determined and modeled as a two-layer medium with 3D finite element mesh. Since numerical algorithms based on finite element methods (FEM) are suitable for complex geometry and boundary conditions, this method is adapted to model the chestwall. Four parameters of bulk absorption and reduced scattering coefficients of the first and second layers are estimated and used to characterize the optical properties of the medium. We used a finite element model based on modified born approximation for image reconstruction. A mismatch correction algorithm has been applied to compensate the mismatch geometry of the breast tissue and chest-wall interface at the reference and the lesion side.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yasaman Ardeshirpour, Minming Huang, and Quing Zhu "An optical tomography method that accounts for a titled chest-wall in breast imaging", Proc. SPIE 7174, Optical Tomography and Spectroscopy of Tissue VIII, 71740U (23 February 2009); https://doi.org/10.1117/12.812105
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Absorption

Breast

Ultrasonography

Optical properties

3D modeling

Tissues

Interfaces

RELATED CONTENT

A two layer model for NIR breast imaging with the...
Proceedings of SPIE (April 28 2005)

Back to Top