14 March 2009 Image-based online correction of misalignment artifacts in cone-beam CT
Y. Kyriakou, R. M. Lapp, L. Hillebrand, D. Ertel, W. A. Kalender
Author Affiliations +
Proceedings Volume 7258, Medical Imaging 2009: Physics of Medical Imaging; 72581V (2009) https://doi.org/10.1117/12.811505
Event: SPIE Medical Imaging, 2009, Lake Buena Vista (Orlando Area), Florida, United States
Abstract
To perform a perspective cone-beam backprojection of the Feldkamp-type (FDK) the geometry of the approximately circular scan trajectory has to be available. If the system or the scan geometry is unknown and afflicted with geometric instabilities (misalignment) reconstructing a misaligned scan can cause severe artifacts in the CT images. We propose an online and image-based iterative correction of a misaligned reconstruction geometry by using entropy minimization. Unlike current methods which use a calibration of the geometry for defined scan protocols and calibration phantoms, the proposed method is performed combining a simplex algorithm for multi-parameter optimization and a graphics card (GPU)-based FDK-reconstruction in an iterative scheme. The simplex algorithm changes the geometric parameters of source and detector with respect to the reduction of entropy. In order to reduce the size of the dimensional space required for minimization the trajectory described by a subset of trajectory points. A virtual trajectory of an approximately circular path is generated after each iteration of the algorithm. This method was validated using simulations and measurements performed on a Carm CT System equipped with a flat-panel detector (Axiom Artis, Siemens Healthcare, Forchheim, Germany). Entropy was minimal for the ideal dataset, whereas strong misalignment resulted in a higher entropy value. The use of the GPU-based reconstruction provided an online geometry correction after a total computation time of only 1-3 s using 100 to 300 iterations of the algorithm, depending on the degree of misalignment and initialization conditions.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Y. Kyriakou, R. M. Lapp, L. Hillebrand, D. Ertel, and W. A. Kalender "Image-based online correction of misalignment artifacts in cone-beam CT", Proc. SPIE 7258, Medical Imaging 2009: Physics of Medical Imaging, 72581V (14 March 2009); https://doi.org/10.1117/12.811505
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications and 5 patents.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Reconstruction algorithms

Calibration

Sensors

Computed tomography

Detection and tracking algorithms

Head

Image quality

Back to Top