Paper
27 February 2009 A template-based approach for the analysis of lung nodules in a volumetric CT phantom study
Author Affiliations +
Proceedings Volume 7260, Medical Imaging 2009: Computer-Aided Diagnosis; 726009 (2009) https://doi.org/10.1117/12.813560
Event: SPIE Medical Imaging, 2009, Lake Buena Vista (Orlando Area), Florida, United States
Abstract
Volumetric CT has the potential to improve the quantitative analysis of lung nodule size change compared to currently used one-dimensional measurement practices. Towards that goal, we have been conducting studies using an anthropomorphic phantom to quantify sources of volume measurement error. One source of error is the measurement technique or software tool used to estimate lesion volume. In this manuscript, we present a template-based approach which utilizes the properties of the acquisition and reconstruction system to quantify nodule volume. This approach may reduce the error associated with the volume estimation technique, thereby improving our ability to estimate the error directly associated with CT parameters and nodule characteristics. Our estimation approach consists of: (a) the simulation of the object-to-image transformation of a helical CT system, (b) the creation of a bank of simulated 3D nodule templates of varying sizes, and (c) the 3D matching of synthetic nodules - that were attached to lung vasculature and scanned with a 16-slice MDCT system - to the bank of simulated templates to estimate nodule volume. Results based on 10 repeat scans for different protocols and a root mean square error (RMSE) similarity metric showed a relative bias of 88%, 14%, and 4% for the measurement of 5 mm, 8 mm and 10 mm low density nodules (-630 HU) compared to -3%, -6%, and 8% for nodules of +100HU density. However, the relative bias for the small, low density nodules (5 mm, -630 HU), was significantly reduced to 7% when a penalized RMSE metric was used to enforce a symmetry constraint that reduced the impact of attached vessels. The results are promising for the use of this measurement approach as a low-bias estimator of nodule volume which will allow the systematic quantification and ranking of measurement error in volumetric CT analysis of lung nodules.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Marios A. Gavrielides, Rongping Zeng, Lisa M. Kinnard, Kyle J. Myers, and Nicholas Petrick "A template-based approach for the analysis of lung nodules in a volumetric CT phantom study", Proc. SPIE 7260, Medical Imaging 2009: Computer-Aided Diagnosis, 726009 (27 February 2009); https://doi.org/10.1117/12.813560
Lens.org Logo
CITATIONS
Cited by 7 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Lung

Error analysis

Computed tomography

Reconstruction algorithms

Image filtering

Scanners

Sensors

Back to Top