Paper
30 December 2008 Isoflurane increases cardiorespiratory coordination in rats
Muammar M. Kabir, Mirza I. Beig, Eugene Nalivaiko, Derek Abbott, Mathias Baumert
Author Affiliations +
Proceedings Volume 7270, Biomedical Applications of Micro- and Nanoengineering IV and Complex Systems; 72700Y (2008) https://doi.org/10.1117/12.810681
Event: SPIE Smart Materials, Nano- and Micro-Smart Systems, 2008, Melbourne, Australia
Abstract
Anesthetics such as isoflurane adversely affect heart rate. In this study we analysed the interaction between heart rhythm and respiration at different concentrations of isoflurane and ventilation rates. In two rats, the electrocardiogram (ECG) and respiratory signals were recorded under the influence of isoflurane. For the assessment of cardiorespiratory coordination, we analysed the phase locking between heart rate, computed from the R-R intervals of body surface ECG, and respiratory rate, computed from impedance changes, using Hilbert transform. The changes in heart rate, percentage of synchronization and duration of synchronized epochs at different isoflurane concentrations and ventilation rates were assessed using linear regression model. From this study it appears that the amount of phase locking between cardiac and respiratory rates increases with the increase in concentration of isoflurane. Heart rate and duration of synchronized epochs increased significantly with the increase in the level of isoflurane concentration while respiratory rate was not significantly affected. Cardiorespiratory coordination also showed a considerable increase at the ventilation rates of 50- 55 cpm in both the rats, suggesting that the phase-locking between the cardiac and respiratory oscillators can be increased by breathing at a particular respiratory frequency.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Muammar M. Kabir, Mirza I. Beig, Eugene Nalivaiko, Derek Abbott, and Mathias Baumert "Isoflurane increases cardiorespiratory coordination in rats", Proc. SPIE 7270, Biomedical Applications of Micro- and Nanoengineering IV and Complex Systems, 72700Y (30 December 2008); https://doi.org/10.1117/12.810681
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Heart

Mode locking

Electrocardiography

Oscillators

Statistical analysis

Software development

Biomedical optics

Back to Top