18 February 2009 High-energy pulsed eye-safe intracavity optical parametric oscillator at 1.57 μm
Author Affiliations +
Abstract
We have demonstrated a high-energy, eye-safe, KTP-based intracavity optical parametric oscillator (IOPO) pumped by a QCW diode-pumped electric-optical Q-switched Nd:YAG. A signal pulse of 31.5mJ energy at 1572nm wavelength was demonstrated at 10Hz with 3.48ns pulse duration. The peak power of the pulses amounted to 9.1MW. The average conversion efficiency from Q-switched 1.064μm wavelength input power to OPO signal output power was up to 10.5%.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yu-Ye Wang, Kai Zhong, De-Gang Xu, Peng Wang, Jian-Quan Yao, "High-energy pulsed eye-safe intracavity optical parametric oscillator at 1.57 μm", Proc. SPIE 7276, Photonics and Optoelectronics Meetings (POEM) 2008: Laser Technology and Applications, 727603 (18 February 2009); doi: 10.1117/12.819879; https://doi.org/10.1117/12.819879