31 December 2009 Systematic errors elimination in two wavelength laser polarimeter
Author Affiliations +
Proceedings Volume 7388, Ninth International Conference on Correlation Optics; 73880X (2009) https://doi.org/10.1117/12.853217
Event: Correlation Optics 2009, 2009, Chernivsti, Ukraine
Abstract
A new approach to the elimination of the main systematic errors in a high-accuracy laser polarimetry tasks is proposed. It is based on using the two lasers with close wavelengths. The measuring method is applied to birefringent and optically active crystals. It is shown, that using the two sources of light allows to except systematic errors more effectively, that conventional HAUP.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yaroslav Shopa, Yaroslav Shopa, Nazar Ftomyn, Nazar Ftomyn, } "Systematic errors elimination in two wavelength laser polarimeter", Proc. SPIE 7388, Ninth International Conference on Correlation Optics, 73880X (31 December 2009); doi: 10.1117/12.853217; https://doi.org/10.1117/12.853217