26 August 2009 CCD radiation damage in ESA Cosmic Visions missions: assessment and mitigation
Author Affiliations +
Abstract
Charge Coupled Device (CCD) imagers have been widely used in space-borne astronomical instruments. A frequent concern has been the radiation damage effects on the CCD charge transfer properties. We review some methods for assessing the Charge Transfer Inefficiency (CTI) in CCDs. Techniques to minimise degradation using background charge injection and p-channel CCD architectures are discussed. A critical review of the claims for p-channel architectures is presented. The performance advantage for p-channel CCD performance is shown to be lower than claimed previously. Finally we present some projections for the performance in the context of some future ESA missions.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
David H. Lumb, David H. Lumb, } "CCD radiation damage in ESA Cosmic Visions missions: assessment and mitigation", Proc. SPIE 7439, Astronomical and Space Optical Systems, 743904 (26 August 2009); doi: 10.1117/12.825284; https://doi.org/10.1117/12.825284