Paper
31 December 2010 Binary optics pyroelectric chopper technology
Xu Hu, Jun Yuan, Li Long
Author Affiliations +
Proceedings Volume 7544, Sixth International Symposium on Precision Engineering Measurements and Instrumentation; 75443H (2010) https://doi.org/10.1117/12.885670
Event: Sixth International Symposium on Precision Engineering Measurements and Instrumentation, 2010, Hangzhou, China
Abstract
It is obvious character that the chopper must be used in Uncooled pyroelectric imaging system. At present, three mainly type chopper which are linear chopper, Archimedean spiral chopper and Fresnel zone plate array (FLA) chopper. The FLA has some advantages than the others, which used diffraction solution. The paper report pyroelectric focal plane binary optics chopper which was processed by laser direct writing etched Fresnel zone plate array shape, and draw the test results: the sub-beam ratio of 1.2 x 103; diffraction efficiency more than 40%; non-uniformity: multi-point test better than 10% in the FLA chopper.
© (2010) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Xu Hu, Jun Yuan, and Li Long "Binary optics pyroelectric chopper technology", Proc. SPIE 7544, Sixth International Symposium on Precision Engineering Measurements and Instrumentation, 75443H (31 December 2010); https://doi.org/10.1117/12.885670
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Diffraction

Sensors

Zone plates

Staring arrays

Modulation

Thermography

Imaging systems

Back to Top