Paper
23 February 2010 Towards real-time 2D/3D registration for organ motion monitoring in image-guided radiation therapy
C. Gendrin, J. Spoerk, C. Bloch, S. A. Pawiro, C. Weber, M. Figl, P. Markelj, F. Pernus, D. Georg, H. Bergmann, W. Birkfellner
Author Affiliations +
Abstract
Nowadays, radiation therapy systems incorporate kV imaging units which allow for the real-time acquisition of intra-fractional X-ray images of the patient with high details and contrast. An application of this technology is tumor motion monitoring during irradiation. For tumor tracking, implanted markers or position sensors are used which requires an intervention. 2D/3D intensity based registration is an alternative, non-invasive method but the procedure must be accelerate to the update rate of the device, which lies in the range of 5 Hz. In this paper we investigate fast CT to a single kV X-ray 2D/3D image registration using a new porcine reference phantom with seven implanted fiducial markers. Several parameters influencing the speed and accuracy of the registrations are investigated. First, four intensity based merit functions, namely Cross-Correlation, Rank Correlation, Mutual Information and Correlation Ratio, are compared. Secondly, wobbled splatting and ray casting rendering techniques are implemented on the GPU and the influence of each algorithm on the performance of 2D/3D registration is evaluated. Rendering times for a single DRR of 20 ms were achieved. Different thresholds of the CT volume were also examined for rendering to find the setting that achieves the best possible correspondence with the X-ray images. Fast registrations below 4 s became possible with an inplane accuracy down to 0.8 mm.
© (2010) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
C. Gendrin, J. Spoerk, C. Bloch, S. A. Pawiro, C. Weber, M. Figl, P. Markelj, F. Pernus, D. Georg, H. Bergmann, and W. Birkfellner "Towards real-time 2D/3D registration for organ motion monitoring in image-guided radiation therapy", Proc. SPIE 7625, Medical Imaging 2010: Visualization, Image-Guided Procedures, and Modeling, 762512 (23 February 2010); https://doi.org/10.1117/12.844201
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image registration

X-rays

X-ray imaging

Volume rendering

Tumors

X-ray computed tomography

Chromium

Back to Top