29 July 2010 Soft x-ray imager (SXI) onboard ASTRO-H
Hiroshi Tsunemi, Kiyoshi Hayashida, Takeshi Go Tsuru, Tadayasu Dotani, Junko S. Hiraga, Naohisa Anabuki, Aya Bamba, Isamu Hatsukade, Takayoshi Kohmura, Koji Mori, Hiroshi Murakami, Hiroshi Nakajima, Masanobu Ozaki, Hiroyuki Uchida, Makoto Yamauchi
Author Affiliations +
Abstract
We are designing an X-ray CCD camera (SXI) for ASTRO-H, including many new items. We have developed the CCD, CCD-NeXT4, that is a P-channel type CCD. It has a thick depletion layer of 200μm with an imaging area of 30mm square. Since it is back-illuminated, it has a good low energy response and is robust against the impact of micro-meteorites. We will employ 4 chips to cover the area of 60mm square. A mechanical rather than peltier cooler will be employed so that we can cool the CCD to -120°C. We will also introduce an analog ASIC that is placed very close to the CCD. It performs well, having a similar noise level to that assembled by using individual parts used on SUZAKU. We also employ a modulated X-ray source (MXS), that improves the accuracy of the calibration. The SXI will have one of the largest SΩ among various satellites.
© (2010) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Hiroshi Tsunemi, Kiyoshi Hayashida, Takeshi Go Tsuru, Tadayasu Dotani, Junko S. Hiraga, Naohisa Anabuki, Aya Bamba, Isamu Hatsukade, Takayoshi Kohmura, Koji Mori, Hiroshi Murakami, Hiroshi Nakajima, Masanobu Ozaki, Hiroyuki Uchida, and Makoto Yamauchi "Soft x-ray imager (SXI) onboard ASTRO-H", Proc. SPIE 7732, Space Telescopes and Instrumentation 2010: Ultraviolet to Gamma Ray, 773210 (29 July 2010); https://doi.org/10.1117/12.856087
Lens.org Logo
CITATIONS
Cited by 13 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Charge-coupled devices

X-rays

Satellites

CCD cameras

Analog electronics

Calibration

Sensors

RELATED CONTENT

Testing fully depleted CCD
Proceedings of SPIE (July 28 2014)
The Soft X ray Imager (SXI) for the ASTRO H...
Proceedings of SPIE (September 18 2015)
CUBIC x ray CCD spectroscopy of the diffuse x...
Proceedings of SPIE (September 01 1995)
Overview of the calibration and the performance of the pn...
Proceedings of SPIE (October 22 1999)
In orbit performance of the EPIC PN CCD camera on...
Proceedings of SPIE (July 18 2000)
CUBIC: preflight calibration results and initial operations
Proceedings of SPIE (October 31 1996)
XIAO a soft x ray telescope for the SVOM...
Proceedings of SPIE (July 15 2008)

Back to Top