30 July 2010 Computation of the off-axis effective area of the New Hard X-ray Mission modules by means of an analytical approach
Author Affiliations +
Abstract
One of the most important parameters determining the sensitivity of X-ray telescopes is their effective area as a function of the X-ray energy. The computation of the effective area of a Wolter-I mirror, with either a single layer or multilayer coating, is a very simple task for a source on-axis at astronomical distance. Indeed, when the source moves off-axis the calculation is more complicated, in particular for new hard X-ray imaging telescopes (NuSTAR, ASTRO-H, NHXM, IXO) beyond 10 keV, that will make use of multilayer coatings to extend the reflectivity band in grazing incidence. Unlike traditional single-layer coatings (in Ir or Au), graded multilayer coatings exhibit an oscillating reflectivity as a function of the incidence angle, which makes the effective area not immediately predictable for a source placed off-axis within the field of view. For this reason, the computation of the off-axis effective area has been so far demanded to raytracing codes, able to sample the incidence of photons onto the mirror assembly. Even if this approach should not be disdained, it would be interesting to approach the same problem from an analytical viewpoint. This would speed up and simplify the computation of the effective area as a function of the off-axis angle, a considerable advantage especially whenever the mirror parameters are still to be optimized. In this work we present the application of a novel, analytical formalism to the computation of the off-axis effective area and the grasp of the NHXM optical modules, requiring only the standard routines for the multilayer reflectivity computation.
© (2010) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
D. Spiga, D. Spiga, V. Cotroneo, V. Cotroneo, } "Computation of the off-axis effective area of the New Hard X-ray Mission modules by means of an analytical approach", Proc. SPIE 7732, Space Telescopes and Instrumentation 2010: Ultraviolet to Gamma Ray, 77322K (30 July 2010); doi: 10.1117/12.855835; https://doi.org/10.1117/12.855835
PROCEEDINGS
8 PAGES


SHARE
RELATED CONTENT

Prototyping iridium coated mirrors for x-ray astronomy
Proceedings of SPIE (May 30 2017)
Multilayer supermirror coating for hard x-ray telescope
Proceedings of SPIE (July 18 1996)
Supermirror design for the XEUS x-ray telescope
Proceedings of SPIE (March 10 2003)
Development of multilayer coatings (Ni C Pt C) for hard...
Proceedings of SPIE (October 10 2004)
Optics For X-Ray Astronomy
Proceedings of SPIE (August 11 1986)

Back to Top