17 May 2011 A novel magnetic field fiber sensor by using magnetic fluid in Sagnac loop
Author Affiliations +
Proceedings Volume 7753, 21st International Conference on Optical Fiber Sensors; 77531G (2011) https://doi.org/10.1117/12.884704
Event: 21st International Conference on Optical Fibre Sensors (OFS21), 2011, Ottawa, Canada
Abstract
A novel magnetic field sensor by using magnetic fluid film in Sagnac loop is presented. The magnetic fluid introduces controllable birefringence under external magnetic field inside the Sagnac loop to produce sinusoidal interference and the corresponding transmission spectrum shifts with the change of external field strength. Sensitivity of 11.4 pm/Oe and resolution of 0.88 Oe are achieved in the case of this proposed scheme.
© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Peng Zu, Peng Zu, Chi Chiu Chan, Chi Chiu Chan, Yongxing Jin, Yongxing Jin, Yifan Zhang, Yifan Zhang, Xinyong Dong, Xinyong Dong, } "A novel magnetic field fiber sensor by using magnetic fluid in Sagnac loop", Proc. SPIE 7753, 21st International Conference on Optical Fiber Sensors, 77531G (17 May 2011); doi: 10.1117/12.884704; https://doi.org/10.1117/12.884704