2 August 2010 Spectroscopy with a coherent dual frequency comb interferometer at 3.4 μm
Author Affiliations +
Abstract
A coherent dual fiber-comb spectrometer centered at 1.5 μm wavelengths is transferred to 3.4 μm by differencefrequency generation with a 1064 nm cw laser. It is shown that the residual linewidth between the comb teeth at 3.4 μm is resolution-limited to 200 mHz; such narrow linewidths can enable coherent dual-comb spectroscopy at high-precision and signal-to-noise ratio. We then discuss different interferometric configurations for coherent dual-comb spectroscopy. We find that a two-branch interferometric setup is appropriate to measure both the magnitude and phase spectrum of purely Doppler-broadened absorption lines. An initial measurement of methane lines in the υ3 band P-branch with a resolution of 114 MHz is demonstrated.
© (2010) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Esther Baumann, Esther Baumann, Fabrizio R. Giorgetta, Fabrizio R. Giorgetta, Ian Coddington, Ian Coddington, William C. Swann, William C. Swann, Nathan R. Newbury, Nathan R. Newbury, } "Spectroscopy with a coherent dual frequency comb interferometer at 3.4 μm", Proc. SPIE 7790, Interferometry XV: Techniques and Analysis, 77900X (2 August 2010); doi: 10.1117/12.859730; https://doi.org/10.1117/12.859730