Paper
10 February 2011 Toward a reference standard for tissue phantoms
Author Affiliations +
Abstract
A reference standard for tissue-simulating phantoms, i.e., a phantom with well known and stable optical properties, reproducible, and easy to be found, would be very useful for many applications based on measurements of diffused light. Although many tissue-equivalent phantoms have been proposed, to our knowledge none of them has been characterized sufficiently well to be suggested as a reference standard. Based on the results of measurements of optical properties we carried out at visible and NIR wavelengths, the use of Intralipid 20% diluted in water as diffusive medium, and of India ink as absorber, is here suggested as a first step towards a diffusive reference standard for tissue-simulating phantoms. As for Intralipid 20%, measurements carried out on samples from nine different batches with expiry dates spreading over ten years showed surprisingly small batch-to-batch variations. For the reduced scattering coefficient the maximum deviation from the value averaged over the nine batches was of about 2%, and the results for the absorption coefficient were very close to those for pure water. As for India ink measurements on samples from different batches and from five different brands showed large inter-brand and inter-batch variations for both the absorption and the extinction coefficient. On the contrary, small variations have been observed for the ratio between the absorption and the extinction coefficient. Intralipid 20% and Indian ink can be therefore easily mixed to obtain liquid phantoms with well known optical properties. This phantom can be a first step towards a reference standard for optical tissue phantoms.
© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Paola Di Ninni, Fabrizio Martelli, and Giovanni Zaccanti "Toward a reference standard for tissue phantoms", Proc. SPIE 7906, Optical Diagnostics and Sensing XI: Toward Point-of-Care Diagnostics; and Design and Performance Validation of Phantoms Used in Conjunction with Optical Measurement of Tissue III, 79060M (10 February 2011); https://doi.org/10.1117/12.874658
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Absorption

Scattering

Optical properties

Tissue optics

Mass attenuation coefficient

Calibration

Optical testing

Back to Top