20 May 2011 RICOR's new development of a highly reliable integral rotary cooler: engineering and reliability aspects
Avishai Filis, Nachman Pundak, Moshe Barak, Ze'ev Porat, Mordechai Jaeger
Author Affiliations +
Abstract
The growing demand for EO applications that work around the clock 24hr/7days a week, such as in border surveillance systems, emphasizes the need for a highly reliable cryocooler having increased operational availability and decreased integrated system Life Cycle (ILS) cost. In order to meet this need RICOR has developed a new rotary Stirling cryocooler, model K508N, intended to double the K508's operating MTTF achieving 20,000 operating MTTF hours. The K508N employs RICOR's latest mechanical design technologies such as optimized bearings and greases, bearings preloading, advanced seals, laser welded cold finger and robust design structure with increased natural frequency compared to the K508 model. The cooler enhanced MTTF was demonstrated by a Validation and Verification (V&V) plan comprising analytical means and a comparative accelerated life test between the standard K508 and the K508N models. Particularly, point estimate and confidence interval for the MTTF improvement factor where calculated periodically during and after the test. The (V&V) effort revealed that the K508N meets its MTTF design goal. The paper will focus on the technical and engineering aspects of the new design. In addition it will discuss the market needs and expectations, investigate the reliability data of the present reference K508 model; and report the accelerate life test data and the statistical analysis methodology as well as its underlying assumptions and results.
© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Avishai Filis, Nachman Pundak, Moshe Barak, Ze'ev Porat, and Mordechai Jaeger "RICOR's new development of a highly reliable integral rotary cooler: engineering and reliability aspects", Proc. SPIE 8012, Infrared Technology and Applications XXXVII, 80122O (20 May 2011); https://doi.org/10.1117/12.884218
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Cryocoolers

Reliability

Accelerated life testing

Data modeling

Mechanical engineering

Electro optical modeling

Standards development

RELATED CONTENT


Back to Top