Paper
14 June 2011 Quantitative photoacoustic blood oxygenation measurement of whole porcine blood samples using a multi-wavelength semiconductor laser system
Claus-Stefan Friedrich, Martin P. Mienkina, Carsten Brenner, Nils C. Gerhardt, Manfred Jörger, Andreas Strauß, Martin F. Beckmann, Georg Schmitz, Martin R. Hofmann
Author Affiliations +
Abstract
We present a photoacoustic measurement system based on semiconductor lasers for blood oxygenation measurements. It permits to use four different optical wavelengths (650nm, 808nm, 850nm, 905nm) to generate photoacoustic signals. As the optical extinction coefficient of oxygenated hemoglobin and deoxygenated hemoglobin is different at specific wavelengths, a blood oxygenation measurement by a multi-wavelength photoacoustic laser system is feasible. Especially at 650nm, the clear difference between the extinction coefficients of the two hemoglobin derivates permits to determine the blood oxygenation in combination with other near infrared wavelengths. A linear model based on tabulated values of extinction coefficients for fully oxygenated and fully deoxygenated hemoglobin is presented. We used heparin stabilized whole porcine blood samples to model the optical behavior of human blood, as the optical absorption behavior of porcine hemoglobin does not differ significantly from human hemoglobin. To determine the real oxygen saturation values of the blood samples, we measured the partial oxygen pressure with an IRMA Trupoint Blood Analysis System. The oxygen saturation values were calculated from a dissociation curve for porcine blood. The results of the photoacoustic measurement are in qualitatively good agreement with the predicted linear model. Further, we analyze the abilities and the limitations of quantitative oxygenation measurements.
© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Claus-Stefan Friedrich, Martin P. Mienkina, Carsten Brenner, Nils C. Gerhardt, Manfred Jörger, Andreas Strauß, Martin F. Beckmann, Georg Schmitz, and Martin R. Hofmann "Quantitative photoacoustic blood oxygenation measurement of whole porcine blood samples using a multi-wavelength semiconductor laser system", Proc. SPIE 8088, Diffuse Optical Imaging III, 808814 (14 June 2011); https://doi.org/10.1117/12.889682
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Blood

Photoacoustic spectroscopy

Oxygen

Semiconductor lasers

Signal detection

Laser systems engineering

Signal generators

Back to Top