11 October 2011 Laser evaporation of models of normal and tumoral biological tissues
Author Affiliations +
Proceedings Volume 8306, Photonics, Devices, and Systems V; 83060H (2011) https://doi.org/10.1117/12.910114
Event: Photonics Prague 2011, 2011, Prague, Czech Republic
Abstract
For study of the dynamics of laser evaporation of model normal and tumoral biotissues the method autodyne detection (self-mixing on laser resonator) of back scattered light from the irradiated zone was used. Biomodels of tumors using of laboratory animals and gelatin models were used. These biomaterials were irradiated by focused beam of CO2 laser 5-10 Watts power with concurrent recording autodyne signal. The level of autodyne signal at laser cutting of multi-layer gelatinous models varies from 1.5 to 3 times at difference of water content in layers from 10 to 30% respectively. The level of autodyne signal as the average power spectrum of this signal varies in different degrees depending on the type of normal and tumoral biotissues at its laser evaporation.
© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
V. A. Ulyanov, A. K. Dmitriev, A. N. Konovalov, V. N. Kortunov, I. V. Reshetov, O. V. Matorin, "Laser evaporation of models of normal and tumoral biological tissues", Proc. SPIE 8306, Photonics, Devices, and Systems V, 83060H (11 October 2011); doi: 10.1117/12.910114; https://doi.org/10.1117/12.910114
PROCEEDINGS