3 April 2012 Electrochemical impedance spectroscopy of the bucky-gel actuators and their electromechanical modeling
Author Affiliations +
Abstract
In this paper, we carried out the impedance measurements of the bucky-gel actuators and analyzed the results by means of the porous electrode model. We also measured the displacement of the same actuators by applying sinusoidal voltages of various frequencies. The frequency dependence of the displacement responses is discussed in relation with the impedance properties of the bucky-gel electrodes. The electrochemical equivalent circuit of the bucky-gel actuator is discussed on the basis of the impedance analysis. Accordingly, we are able to develop an electrochemical model allowing to analyze the behavior of these actuators.
© (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Kinji Asaka, Kinji Asaka, Kenji Kiyohara, Kenji Kiyohara, Takushi Sugino, Takushi Sugino, Ken Mukai, Ken Mukai, Hyacinthe Randriamahazaka, Hyacinthe Randriamahazaka, } "Electrochemical impedance spectroscopy of the bucky-gel actuators and their electromechanical modeling", Proc. SPIE 8340, Electroactive Polymer Actuators and Devices (EAPAD) 2012, 83402M (3 April 2012); doi: 10.1117/12.917392; https://doi.org/10.1117/12.917392