18 May 2012 Microscale thermal analysis with cooled and uncooled infrared cameras
Author Affiliations +
Abstract
Uncooled micro-bolometer of 17 μm pitch has been successfully applied to the micro-scale thermal analysis with a newly designed optics, the emissivity corrected procedure, and the quasi-acceleration of time frame method. The spatial resolution of 11 μm in a good balance of MTF and N.A. has been achieved for the optics of VOx FPA. It enables to visualize the exothermic latent heat of freezing biological cells at a minus temperature. The emissivity corrected microscale thermal imaging using a real time direct impose-signal system is presented both with VOx and InSb FPA.
© (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Junko Morikawa, Eita Hayakawa, Toshimasa Hashimoto, "Microscale thermal analysis with cooled and uncooled infrared cameras", Proc. SPIE 8354, Thermosense: Thermal Infrared Applications XXXIV, 835410 (18 May 2012); doi: 10.1117/12.918252; https://doi.org/10.1117/12.918252