Paper
13 September 2012 First on-sky calibration of an high order adaptive optics system
Author Affiliations +
Abstract
The AO system calibration is usually done with a dedicated setup during daytime. Here we present results of two alternative techniques as the synthetic and the on-sky interaction matrix calibration. In both cases we created matrices controlling 400 modes of the LBT-FLAO system. We present here the performances reached on-sky at LBT compared with those obtained with the standard calibration. The described techniques allow calibrating the AO system without any dedicated hardware. This is particularly attractive for systems that require complex calibration setup such as those with a convex adaptive secondary like the MMT and the planned VLT AOF.
© (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
E. Pinna, F. Quirós-Pacheco, A. Riccardi, R. Briguglio, A. Puglisi, L. Busoni, C. Arcidiacono, J. Argomedo, M. Xompero, E. Marchetti, and S. Esposito "First on-sky calibration of an high order adaptive optics system", Proc. SPIE 8447, Adaptive Optics Systems III, 84472B (13 September 2012); https://doi.org/10.1117/12.927152
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

Adaptive optics

Modulation

Mirrors

Signal to noise ratio

Stars

Telescopes

RELATED CONTENT