30 November 2012 PH sensor using fiber Bragg grating based on swelling of hydrogel
Author Affiliations +
Abstract
To achieve pH detection of multi-points, a new pH sensor based on pH sensitive hydrogel swelling detection by a fiber Bragg grating is proposed. The deflection of a silica membrane due to pH value change induced hydrogel swelling is measured by the center wavelength shifts of a fiber Bragg grating epoxied on the membrane. The relation between center wavelength shifts of the fiber Bragg grating with the hydrogel swelling behavior was studied experimentally. Around 100pm shift of the fiber Bragg grating center wavelength was observed when the pH value was changed from 4 to 7 or from 7 to 10 by using pH standard solutions, which fundamentally proved the feasibility of this method for pH detection.
© (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Xiaohua Lei, Xiaohua Lei, Bo Dong, Bo Dong, Jianmin Gong, Jianmin Gong, Anbo Wang, Anbo Wang, Weimin Chen, Weimin Chen, } "PH sensor using fiber Bragg grating based on swelling of hydrogel", Proc. SPIE 8561, Advanced Sensor Systems and Applications V, 856111 (30 November 2012); doi: 10.1117/12.999513; https://doi.org/10.1117/12.999513
PROCEEDINGS
6 PAGES


SHARE
Back to Top