Paper
6 March 2013 Fast iterative beam hardening correction based on frequency splitting in computed tomography
Qiao Yang, Matthias Elter, Ingo Schasiepen, Nicole Maass, Joachim Hornegger
Author Affiliations +
Proceedings Volume 8668, Medical Imaging 2013: Physics of Medical Imaging; 86682J (2013) https://doi.org/10.1117/12.2007808
Event: SPIE Medical Imaging, 2013, Lake Buena Vista (Orlando Area), Florida, United States
Abstract
In computed tomography (CT), the nonlinear characteristics of beam hardening are due to the polychromaticity of X-rays, which severely degrade the CT image quality and diagnostic accuracy. The correction of beam hardening has been an active area since the early years of CT, and various techniques have been developed. State­ of-the-art works on multi-material beam hardening correction (BHC) are mainly based on segmenting datasets into different materials, and correcting the non-linearity iteratively. Those techniques are limited in correction effectiveness due to inaccurate segmentation. Furthermore, most of them are computationally intensive. In this study, we introduce a fast BHC scheme based on frequency splitting with the fact that beam hardening artifacts mainly contain in the low frequency components and take more iterations to be corrected in comparison with high frequency components. After low-pass filtering and correcting artifacts at down-sampled projections, an artifact reduced high resolution reconstruction will be obtained by incorporating the original edge information from the high frequency components. Evaluations in terms of correction accuracy and computational efficiency are performed using simulated and real CT datasets. In comparison to the BHC algorithm without frequency splitting, the proposed accelerated algorithm yields comparable results in correcting cupping and streak artifacts with tremendously reduced computational effort. We conclude that the presented framework can achieve a significant speedup while still obtaining excellent artifact reduction. This is a significant practical advantage for clinical as well as industrial CT.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Qiao Yang, Matthias Elter, Ingo Schasiepen, Nicole Maass, and Joachim Hornegger "Fast iterative beam hardening correction based on frequency splitting in computed tomography", Proc. SPIE 8668, Medical Imaging 2013: Physics of Medical Imaging, 86682J (6 March 2013); https://doi.org/10.1117/12.2007808
Lens.org Logo
CITATIONS
Cited by 7 scholarly publications and 1 patent.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Reconstruction algorithms

Image segmentation

X-rays

Beam splitters

Image resolution

Computed tomography

Signal attenuation

Back to Top