19 April 2013 Active mass damper system employing time delay control algorithm for vibration mitigation of building structure
Author Affiliations +
Abstract
The feasibility of an active mass damper (AMD) system employing the time delay control (TDC) algorithm, which is one of the robust and adaptive control algorithms, for effectively suppressing the wind-induced vibration of a building structure is investigated. The TDC algorithm has several attractive features such as the simplicity and the excellent robustness to unknown system dynamics and disturbance. Based on the characteristics of the algorithm, it has the potential to be an effective control system for mitigating excessive vibration of civil engineering structures such as buildings, bridges and towers. However, it has not been used for structural response reduction yet. In order to verify the effectiveness of the proposed active control method combining an AMD system with the TDC algorithm, a series of labscale tests are carried out.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Dong-Doo Jang, Dong-Doo Jang, Jeongsu Park, Jeongsu Park, Hyung-Jo Jung, Hyung-Jo Jung, } "Active mass damper system employing time delay control algorithm for vibration mitigation of building structure", Proc. SPIE 8692, Sensors and Smart Structures Technologies for Civil, Mechanical, and Aerospace Systems 2013, 86923Z (19 April 2013); doi: 10.1117/12.2010012; https://doi.org/10.1117/12.2010012
PROCEEDINGS
5 PAGES


SHARE
Back to Top