Paper
31 May 2013 Spectral observation of fuel additives in gasoline-ethanol blends using a Fourier-transform Raman spectrometer prototype
Valentin Ortega Clavero, Nicolas Javahiraly, Andreas Weber, Werner Schröder, Patrick Meyrueis
Author Affiliations +
Abstract

The combination of fossil fuels with bio-fuels, specially ethanol and methanol, has acquired relevance and attention in several countries in recent years. A variety of factors have induced this trend: market prices, constant geopolitical events, new sustainability policies and laws, etc. The fuels used in the automotive industry, including bio-fuels, normally contain additives as anti-shock agents and as octane booster. These additives may endanger (beside the high volatility implied) public health or environment due to the nature of its chemical composition.

Raman spectral information from different additives, specially toluene, contained in E10 gasoline-ethanol blends has been obtained by using an own-design Fourier-Transform Raman spectrometer (FT-Raman). This information has been also compared with Raman spectra from pure additives and with standard Raman lines in order to validate its accuracy in frequency. The spectral information is presented in the range of 0 cm−1 to 3500 cm−1 with a resolution of 1.66 cm−1. The Raman spectra obtained shows a reduced frequency deviation (less than 0.4 cm−1 when compared to standard Raman spectra from different calibration materials, e.g. cyclohexane and toluene, without compensation for instrumental response).

The Fourier-Transform Raman spectrometer prototype used for the spectral analysis, consisting of a Michelson interferometer and a self-designed photon counter cooled down on a three stage Peltier element arrangement, is able to extract high resolution and precise Raman spectra from the additives in the fuels analyzed. The proposed FT-Raman prototype has no additional complex hardware or software control. The mechanical and thermal disturbances affecting the FT-Raman system are mathematically compensated by extracting the optical path information from the generated interference pattern of λ = 632.8nm Helium-Neon laser (HeNe laser), which is used at the spectrum evaluation. This allows the device to be used in complicated environments where certain level of security is required (e.g. fuel production, storage, transportation, etc.).

© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Valentin Ortega Clavero, Nicolas Javahiraly, Andreas Weber, Werner Schröder, and Patrick Meyrueis "Spectral observation of fuel additives in gasoline-ethanol blends using a Fourier-transform Raman spectrometer prototype", Proc. SPIE 8720, Photonic Applications for Aerospace, Commercial, and Harsh Environments IV, 87200L (31 May 2013); https://doi.org/10.1117/12.2018484
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Raman spectroscopy

Spectroscopy

Prototyping

Photon counting

Chemical compounds

Helium neon lasers

Michelson interferometers

Back to Top