Paper
4 March 2013 Halo performance on low light level image intensifiers
Author Affiliations +
Proceedings Volume 8761, PIAGENG 2013: Image Processing and Photonics for Agricultural Engineering; 876108 (2013) https://doi.org/10.1117/12.2019621
Event: Third International Conference on Photonics and Image in Agriculture Engineering (PIAGENG 2013), 2013, Sanya, China
Abstract
To analyze the formation mechanism of the halo on low light level image intensifiers and the influencing factors on the halo size, a halo tester has been designed. Under the illumination between 10-2 lx and 10-4 lx, we use the tester to collect a 0.1922 mm hole image directly with CoolSNAPK4 charge-coupled device (CCD) in a darkroom. The practical measurement result shows that the amplification ratio is 343.4. Then we put the super second and third generation image intensifiers after the hole, and the halo sizes of the hole images on the screens are determined as 0.2388 and 0.5533 mm respectively. The results are helpful to improve the quality of the low light level image intensifiers.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Dongxu Cui, Ling Ren, Benkang Chang, Feng Shi, Jifang Shi, Yunsheng Qian, Honggang Wang, and Junju Zhang "Halo performance on low light level image intensifiers", Proc. SPIE 8761, PIAGENG 2013: Image Processing and Photonics for Agricultural Engineering, 876108 (4 March 2013); https://doi.org/10.1117/12.2019621
Lens.org Logo
CITATIONS
Cited by 1 patent.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image intensifiers

Charge-coupled devices

Microchannel plates

Integrating spheres

Light sources

Scattering

Image processing

Back to Top