You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
3 May 2013Differential length measurement using low coherence coupled tandem interferometry
This paper presents the use of low coherence coupled tandem interferometry to measure the differential length of two independent Fabry-Perot (F-P) type microcavities. The two discrete F-P type microcavities are formed between the cleaved end of a fibre and a reflective surface, which could for example, be a pressure sensing membrane or any other component of a transducing element. The technique is an all-optical fibre based sensing configuration in which the sensing cavities are at widely separated locations in an environment where strong temperature gradients may exist. The sensing system is based on two sequential cavities arranged in tandem. The lengths of the cavities are probed by a temperature stabilised fibre based Michelson interferometer operating with a broadband light source. One arm of the probing Michelson interferometer is scanned using a piezo fibre stretcher resulting in an optical path length difference (OPD) between the two arms. The optical interconnecting leads from the probing Michelson interferometer to the two F-P locations are not an active part of the sensor configuration and therefore this configuration is largely insensitive to temperature and strain effects on these interconnecting leads. It is only the probing Michelson interferometer which has to be temperature stabilised. This arrangement allows the F-P measurement cavities to be separated by distances in the range of tens of meters.
The alert did not successfully save. Please try again later.
Martin D. Smith, William N. MacPherson, Robert R. J. Maier, "Differential length measurement using low coherence coupled tandem interferometry," Proc. SPIE 8774, Optical Sensors 2013, 87740T (3 May 2013); https://doi.org/10.1117/12.2017591