Paper
18 November 2013 Validation of dose measurements by scintillating fiber optic dosimeters for medical applications
Author Affiliations +
Proceedings Volume 8785, 8th Iberoamerican Optics Meeting and 11th Latin American Meeting on Optics, Lasers, and Applications; 8785F5 (2013) https://doi.org/10.1117/12.2026880
Event: 8th Ibero American Optics Meeting/11th Latin American Meeting on Optics, Lasers, and Applications, 2013, Porto, Portugal
Abstract
Organic scintillators have been promoted and widely used in scintillating fiber-optic dosimeters (SFOD) due to their tissue-equivalent characteristics, small sensitive volume combined with high spatial resolution, and emission of visible light proportional to the absorbed electron and gamma dose rate. In this paper we will present the validation of Monte Carlo simulations of dose measurements assisted by scintillating fiber optic dosimeters operating in the visible spectral range, in the context of the development of fiber optic dosimeters targeted to Brachytherapy. The Monte Carlo simulation results are compared to measurements performed with SFOD test probes, assembled with BCF-60 (Saint Gobain) samples of 1 mm diameter and 0.35 to 1.5 cm length, coupled to PMMA optical fiber. The optical signal resulting from scintillation and Cherenkov light is transmitted through an additional optical fiber link to a remote measuring device. For SFOD probes irradiation a dedicated PMMA phantom was used. The results were validated against measurements obtained with a properly calibrated pinpoint ionization chamber (PTW). The probes were positioned in a radial arrangement, with a radioactive source at its center point. The γ-rays source is a Nucletron Microselectron-V2 192Ir. The dose curves are obtained according to the different positions in the phantom with the SFOD dosimeters. The system is able to use a Fiber Optic Multiplexer (FOM) controlled with Labview software.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
A. Correia, R. Pirraco, and C. C. Rosa "Validation of dose measurements by scintillating fiber optic dosimeters for medical applications", Proc. SPIE 8785, 8th Iberoamerican Optics Meeting and 11th Latin American Meeting on Optics, Lasers, and Applications, 8785F5 (18 November 2013); https://doi.org/10.1117/12.2026880
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Monte Carlo methods

Fiber optics

Sensors

Signal detection

Polymethylmethacrylate

Ionization

Scintillators

RELATED CONTENT

Fiber Optic Non-Contact Temperature Probe System
Proceedings of SPIE (April 28 1987)
Fiber optic gradient hydrophones
Proceedings of SPIE (September 14 1994)

Back to Top