16 May 2013 Experimental study on laser beam diagnostics based on fiber array
Author Affiliations +
Proceedings Volume 8796, 2nd International Symposium on Laser Interaction with Matter (LIMIS 2012); 87961X (2013) https://doi.org/10.1117/12.2011084
Event: 2nd International Symposium on Laser Interaction with Matter (LIMIS 2012), 2012, Xi'an, Shaanxi, China
Abstract
A method for direct laser beam diagnostics based on fiber array is introduced. The designing principle and configuration of the method are presented. The experimental results show that it can provide laser power density distribution information with a high spatial resolution better than 3mm and with an error of measurement less than 3%. The theoretical analysis by finite element method(FEM) for laser radiation indicates that this method should be used to measure the high energy laser beam with diameter of several hundred millimeters for tens of seconds. In addition, the results of fiber array technique are compared, qualitatively, with the spatial beam profile obtained by a near infrared charge coupled device(NIR-CCD). These two methods yield consistent results.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yong Wu, Yong Wu, Pengling Yang, Pengling Yang, Ping Wang, Ping Wang, Weiping Liu, Weiping Liu, Zhenbao Wang, Zhenbao Wang, Junjie Wu, Junjie Wu, Xisheng Ye, Xisheng Ye, } "Experimental study on laser beam diagnostics based on fiber array", Proc. SPIE 8796, 2nd International Symposium on Laser Interaction with Matter (LIMIS 2012), 87961X (16 May 2013); doi: 10.1117/12.2011084; https://doi.org/10.1117/12.2011084