Paper
26 September 2013 Diagnostic Instrument Manipulator (DIM) upgrades for reliability and operational efficiency in a radiological contamination environment at the National Ignition Facility (NIF)
Author Affiliations +
Abstract
The Diagnostic Instrument Manipulators (DIMs) are two-staged, telescoping systems that allow the precise alignment and positioning of various x-ray, optical, nuclear, and other diagnostics in the National Ignition Facility (NIF) Target Chamber. Designed to be reconfigurable and exchangeable between NIF experiments, the second stage of the DIM is referred to as the Diagnostic Load Package (DLP), which is most often comprised of a cart, diagnostic, and detachable snout. As experiments continue to increase radiation levels, various upgrades have been made to the DIMs to improve reliability and operational efficiency. These upgrades reduce worker exposure and increase experimental shot rates. Specific to this paper, the design and operation of dedicated DLP handling and storage units (DHUs and DSUs) are discussed in addition to their transport equipment. Hardware and process improvements for reduced worker exposure during general DIM access are also featured. Finally, the DLP limit switches have been upgraded to magneticallyactuated proximity sensors for reliability, improved shot rate, and increased user flexibility.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Robert Plummer "Diagnostic Instrument Manipulator (DIM) upgrades for reliability and operational efficiency in a radiological contamination environment at the National Ignition Facility (NIF)", Proc. SPIE 8850, Target Diagnostics Physics and Engineering for Inertial Confinement Fusion II, 885005 (26 September 2013); https://doi.org/10.1117/12.2024524
Lens.org Logo
CITATIONS
Cited by 8 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Diagnostics

Digital Light Processing

National Ignition Facility

Contamination

Switches

Control systems

Reliability

Back to Top