Paper
11 September 2013 MTF measurement of IRFPA based on double-knife edge scanning method
Cheng-ping Ying, Bin Wu, Heng-fei Wang, Xue-shun Shi, Hong-yuan Liu
Author Affiliations +
Proceedings Volume 8907, International Symposium on Photoelectronic Detection and Imaging 2013: Infrared Imaging and Applications; 890746 (2013) https://doi.org/10.1117/12.2034552
Event: ISPDI 2013 - Fifth International Symposium on Photoelectronic Detection and Imaging, 2013, Beijing, China
Abstract
Modulation transfer function (MTF) is one of the most important parameters of infrared focal plane array (IRFPA). A double-knife edge scanning method is proposed for MTF measurement of IRFPA. In this method, a double-knife edge was used as a target, and the IRFPA under test was positioned in the focal plane of the imaging optical system by a 3-axis translation stage. With an IRFPA data acquisition system, the image of the double-knife edge was restored. By scanning in the direction orthogonal to the double-knife edge image, edge spread function (ESF) curve of each pixel swept across the knife-edge image was obtained. MTF could be calculated from the subsequent fitting, differential and Fourier transformation procedures. With double-knife edge scanning, two ESF curves of double-knife edge were obtained simultaneously, and symmetry of the two ESF curves could be used to evaluate the verticality between photosensitive surface of IRFPA and optical axis of the double-knife edge imaging system. In addition, this method can be used to judge the existing of interference from outside such as vibration, stray light and electrical noise. A measurement facility for IRFPA’s MTF based on double-knife edge scanning method was also established in this study. The facility is composed of double-knife edge imaging optical system, 3-axis translation stage and data acquisition system, et al. As the kernel of the facility, the double-knife edge imaging optical system mainly comprises two symmetrical parabolic mirrors coating with reflective material, and the magnification of the optical system is 1 with an operation wavelength range of (1∼14) μm.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Cheng-ping Ying, Bin Wu, Heng-fei Wang, Xue-shun Shi, and Hong-yuan Liu "MTF measurement of IRFPA based on double-knife edge scanning method", Proc. SPIE 8907, International Symposium on Photoelectronic Detection and Imaging 2013: Infrared Imaging and Applications, 890746 (11 September 2013); https://doi.org/10.1117/12.2034552
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Modulation transfer functions

Imaging systems

Optical imaging

Data acquisition

Infrared imaging

Reflectors

Infrared radiation

RELATED CONTENT


Back to Top