28 February 2014 The Uppsala Contrast Sensitivity Test (UCST): A fast strategy for clinical assessment of contrast sensitivity
Author Affiliations +
Proceedings Volume 8930, Ophthalmic Technologies XXIV; 89300H (2014) https://doi.org/10.1117/12.2054403
Event: SPIE BiOS, 2014, San Francisco, California, United States
Abstract
Routine clinical measurement of spectral contrast sensitivity is hampered by the time consumption of current methods. We are developing a system that allows instantaneous measurement of spectral contrast sensitivity. The UCST system consists of custom software running on an iPad connected to a calibrated TFT-monitor. Twenty healthy subjects were consecutively randomized to have their spectral contrast sensitivity measured with the UCST strategy or with a Vistech VCTS 6500 chart. The examination time and the spectral contrast sensitivity, respectively, were recorded for each eye in each subject. The Vistech strategy resulted in a more extended mean examination time (CI-Vistech:± (0.95) = 87 ±27 s, d.f. = 9) than the UCST strategy (CI-UCST:μ (0.95) = 13 ±4 s, d.f. = 9), and the estimated mean difference between the two strategies indicated a difference in examination time (CI-difference:μ (0.95) = [47;106] s, d.f. = 18). The overall contrast sensitivity for each group was estimated as the contrast sensitivities for the spatial frequencies sampled, integrated over the spatial frequency band sampled. The Vistech strategy resulted in a higher estimated mean overall contrast sensitivity (CI-Vistech:μ (0.95) = 116±24 log rel.·log [c.·deg-1], d.f. = 9) than the UCST strategy (CIUCST: μ (0.95) = 74±14 log rel.·log [c.·deg-1], d.f. = 9), and the estimated mean difference between the two strategies indicated a difference in overall contrast sensitivity (CI-difference:μ (0.95) = [15;68] log rel.·log [c.·deg-1]), d.f. = 18). It is concluded that the UCST strategy measures spectral contrast sensitivity on the order of 7 times faster than the Vistech strategy. The slightly lower overall contrast sensitivity recorded for the UCST strategy appeared to be due to a limitation in dynamic range that can be overcome with improved design.
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Lars D. Malmqvist, Per G. Söderberg, "The Uppsala Contrast Sensitivity Test (UCST): A fast strategy for clinical assessment of contrast sensitivity", Proc. SPIE 8930, Ophthalmic Technologies XXIV, 89300H (28 February 2014); doi: 10.1117/12.2054403; https://doi.org/10.1117/12.2054403
PROCEEDINGS
8 PAGES


SHARE
RELATED CONTENT

Optimum viewing distance for target acquisition
Proceedings of SPIE (May 12 2015)
Capability of the human visual system
Proceedings of SPIE (September 10 2003)
The Scratch Standard Is Only A Cosmetic Standard
Proceedings of SPIE (December 20 1989)
Visual aspects of picture storage
Proceedings of SPIE (March 01 1991)

Back to Top