3 February 2014 MFP scanner diagnostics using a self-printed target to measure the modulation transfer function
Author Affiliations +
Abstract
In the current market, reduction of warranty costs is an important avenue for improving profitability by manufacturers of printer products. Our goal is to develop an autonomous capability for diagnosis of printer and scanner caused defects with mid-range laser multifunction printers (MFPs), so as to reduce warranty costs. If the scanner unit of the MFP is not performing according to specification, this issue needs to be diagnosed. If there is a print quality issue, this can be diagnosed by printing a special test page that is resident in the firmware of the MFP unit, and then scanning it. However, the reliability of this process will be compromised if the scanner unit is defective. Thus, for both scanner and printer image quality issues, it is important to be able to properly evaluate the scanner performance. In this paper, we consider evaluation of the scanner performance by measuring its modulation transfer function (MTF). The MTF is a fundamental tool for assessing the performance of imaging systems. Several ways have been proposed to measure the MTF, all of which require a special target, for example a slanted-edge target. It is unacceptably expensive to ship every MFP with such a standard target, and to expect that the customer can keep track of it. To reduce this cost, in this paper, we develop new approach to this task. It is based on a self-printed slanted-edge target. Then, we propose algorithms to improve the results using a self-printed slanted-edge target. Finally, we present experimental results for MTF measurement using self-printed targets and compare them to the results obtained with standard targets.
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Weibao Wang, Weibao Wang, Peter Bauer, Peter Bauer, Jerry Wagner, Jerry Wagner, Jan P. Allebach, Jan P. Allebach, } "MFP scanner diagnostics using a self-printed target to measure the modulation transfer function", Proc. SPIE 9016, Image Quality and System Performance XI, 90160A (3 February 2014); doi: 10.1117/12.2037959; https://doi.org/10.1117/12.2037959
PROCEEDINGS
9 PAGES


SHARE
RELATED CONTENT

Optimum parameters in image intensifier MTF measurements
Proceedings of SPIE (December 06 2004)
Characterization of printer MTF
Proceedings of SPIE (January 17 2006)
Review Of German Standards On Image Assessment
Proceedings of SPIE (October 12 1977)

Back to Top