19 March 2014 Pooling optimal combinations of energy thresholds in spectroscopic CT
Thomas Koenig, Marcus Zuber, Elias Hamann, Armin Runz, Michael Fiederle, Tilo Baumbach
Author Affiliations +
Abstract
Photon counting detectors used in spectroscopic CT are often based on small pixels and therefore offer only limited space to include energy discriminators and their associated counters in each pixel cell. For this reason, it is important to make efficient use of the available energy discriminators in order to achieve an optimized material contrast at a radiation dose as low as possible. Unfortunately, the complexity of evaluating every possible combination of energy thresholds, given a fixed number of counters, rapidly increases with the resolution at which this search is performed, and makes brute-force approaches to this problem infeasible. In this work, we introduce methods from machine learning, in particular sparse regression, to perform a feature selection to determine optimal combinations of energy thresholds. We will demonstrate how methods enforcing row-sparsity on a linear regression’s coefficient matrix can be applied to the multiple response problem in spectroscopic CT, i.e. the case in which a single set of energy thresholds is sought to simultaneously retrieve concentrations pertaining to a multitude of materials in an optimal way. These methods are applied to CT images experimentally obtained with a Medipix3RX detector operated in charge summing mode and with a CdTe sensor at a pixel pitch of 110μm. We show that the least absolute shrinkage and selection operator (lasso), generalized to the multiple response case, chooses four out of 20 possible threshold positions that allow discriminating PMMA, iodine and gadolinium in a contrast agent phantom at a higher accuracy than with equally spaced thresholds. Finally, we illustrate why it might be unwise to use a higher number of energy thresholds than absolutely necessary.
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Thomas Koenig, Marcus Zuber, Elias Hamann, Armin Runz, Michael Fiederle, and Tilo Baumbach "Pooling optimal combinations of energy thresholds in spectroscopic CT", Proc. SPIE 9033, Medical Imaging 2014: Physics of Medical Imaging, 90331A (19 March 2014); https://doi.org/10.1117/12.2043400
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Spectroscopy

Sensors

Feature selection

Gadolinium

Iodine

Imaging spectroscopy

Computed tomography

Back to Top