19 March 2014 Design of anthropomorphic textured phantoms for CT performance evaluation
Author Affiliations +
Abstract
Commercially available computed tomography (CT) technologies such as iterative reconstruction (IR) have the potential to enable reduced patient doses while maintaining diagnostic image quality. However, systematically determining safe dose reduction levels for IR algorithms is a challenging task due to their nonlinear nature. Most attempts to evaluate IR algorithms rely on measurements made in uniform phantoms. Such measurements may overstate the dose reduction potential of IR because they don’t account for the complex relationship between anatomical variability and image quality. The purpose of this study was to design anatomically informed textured phantoms for CT performance evaluation. Two phantoms were designed to represent lung and soft-tissue textures. The lung phantom includes intricate vessel-like structures along with embedded nodules (spherical, lobulated, and spiculated). The soft tissue phantom was designed based on a three-dimensional clustered lumpy background with included low-contrast lesions (spherical and anthropomorphic). The phantoms were built using rapid prototyping (3D printing) technology and imaged on a modern multi-slice clinical CT scanner to assess the noise performance of a commercial IR algorithm in the context of uniform and textured backgrounds. Fifty repeated acquisitions were acquired for each background type and noise was assessed by measuring pixel standard deviation, across the ensemble of repeated acquisitions. For pixels in uniform areas, the IR algorithm reduced noise magnitude (STD) by 60% (compared to FBP). However, for edge pixels, the noise magnitude in the IR images ranged from 20% higher to 40% lower compared to FBP. In all FBP images and in IR images of the uniform phantom, noise appeared to be globally non-stationary (i.e., spatially dependent) but locally stationary (within a reasonably small region of interest). In the IR images of the textured phantoms, the noise was globally and locally non-stationary.
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Justin Solomon, François Bochud, and Ehsan Samei "Design of anthropomorphic textured phantoms for CT performance evaluation", Proc. SPIE 9033, Medical Imaging 2014: Physics of Medical Imaging, 90331U (19 March 2014); https://doi.org/10.1117/12.2043555
Lens.org Logo
CITATIONS
Cited by 12 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Infrared imaging

Lung

3D printing

Denoising

Computed tomography

Reconstruction algorithms

Image quality

Back to Top