Open Access Paper
21 June 1988 Development Of Antibody-Based Fiber-Optic Sensors
Bruce J. Tromberg, Michael J. Sepaniak, Tuan Vo-Dinh
Author Affiliations +
Proceedings Volume 0906, Optical Fibers in Medicine III; (1988) https://doi.org/10.1117/12.945251
Event: 1988 Los Angeles Symposium: O-E/LASE '88, 1988, Los Angeles, CA, United States
Abstract
The speed and specificity characteristic of immunochemical complex formation has encouraged the development of numerous antibody-based analytical techniques. The scope and versatility of these established methods can be enhanced by combining the principles of conventional immunoassay with laser-based fiber-optic fluorimetry. This merger of spectroscopy and immunochemistry provides the framework for the construction of highly sensitive and selective fiber-optic devices (fluoroimmuno-sensors) capable of in-situ detection of drugs, toxins, and naturally occurring biochemicals. Fluoroimmuno-sensors (FIS) employ an immobilized reagent phase at the sampling terminus of a single quartz optical fiber. Laser excitation of antibody-bound analyte produces a fluorescence signal which is either directly proportional (as in the case of natural fluorophor and "antibody sandwich" assays) or inversely proportional (as in the case of competitive-binding assays) to analyte concentration. Factors which influence analysis time, precision, linearity, and detection limits include the nature (solid or liquid) and amount of the reagent phase, the method of analyte delivery (passive diffusion, convection, etc.), and whether equilibrium or non-equilibrium assays are performed. Data will be presented for optical fibers whose sensing termini utilize: (1) covalently-bound solid antibody reagent phases, and (2) membrane-entrapped liquid antibody reagents. Assays for large-molecular weight proteins (antigens) and small-molecular weight, carcinogenic, polynuclear aromatics (haptens) will be considered. In this manner, the influence of a system's chemical characteristics and measurement requirements on sensor design, and the consequence of various sensor designs on analytical performance will be illustrated.
© (1988) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Bruce J. Tromberg, Michael J. Sepaniak, and Tuan Vo-Dinh "Development Of Antibody-Based Fiber-Optic Sensors", Proc. SPIE 0906, Optical Fibers in Medicine III, (21 June 1988); https://doi.org/10.1117/12.945251
Lens.org Logo
CITATIONS
Cited by 45 scholarly publications and 19 patents.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Optical fibers

Luminescence

Fiber optics sensors

Molecules

Medicine

Solids

RELATED CONTENT

Lifetime imaging with optical fibers
Proceedings of SPIE (December 09 1999)
Near-infrared fluorescent dyes for fiber optic sensing
Proceedings of SPIE (May 23 2005)
Laser-based fiberoptic immunosensors
Proceedings of SPIE (March 09 1993)
Molecular beacon biosensors for DNA/RNA analysis
Proceedings of SPIE (March 22 2000)
Sensitive fiber-optic immunoassay
Proceedings of SPIE (July 01 1991)

Back to Top