23 July 2014 Large area TES spiderweb bolometer for multi-mode cavity microwave detect
Author Affiliations +
Abstract
Large area spiderweb bolometers of 8 mm diameter and a mesh size of 250 μm are fabricated in order to couple with approximately the first 20 modes of a multimode EM cavity at about 140 GHz. The sensor is a Ti/Au/Ti 3 layer TES with Tc tuned in the 330-380 mK and 2 mK transition width. We describe the detector design and the fabrication process, early TES electro-thermal measurements. We also report optical coupling measurement and show the multimode coupling.
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
M. Biasotti, M. Biasotti, D. Bagliani, D. Bagliani, V. Ceriale, V. Ceriale, D. Corsini, D. Corsini, P. De Bernardis, P. De Bernardis, F. Gatti, F. Gatti, R. Gualtieri, R. Gualtieri, L. Lamagna, L. Lamagna, S. Masi, S. Masi, G. Pizzigoni, G. Pizzigoni, A. Schillaci, A. Schillaci, } "Large area TES spiderweb bolometer for multi-mode cavity microwave detect", Proc. SPIE 9153, Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy VII, 915308 (23 July 2014); doi: 10.1117/12.2057071; https://doi.org/10.1117/12.2057071