8 September 2014 Optical design and tolerancing of an ophthalmological system
Author Affiliations +
Abstract
Tolerance analysis by means of simulation is an essential step in system integration. Tolerance analysis allows for predicting the performance of a system setup of real manufactured parts and for an estimation of the yield with respect to evaluation figures, such as performance requirements, systems specification or cost demands. Currently, optical freeform optics is gaining importance in optical systems design. The performance of freeform optics often strongly depends on the manufacturing accuracy of the surfaces. For this reason, a tolerance analysis with respect to the fabrication accuracy is of crucial importance. The characterization of form tolerances caused by the manufacturing process is based on the definition of straightness, flatness, roundness, and cylindricity. In case of freeform components, however, it is often impossible to define a form deviation by means of this standard classification. Hence, prediction of the impact of manufacturing tolerances on the optical performance is not possible by means of a conventional tolerance analysis. To carry out a tolerance analysis of the optical subsystem, including freeform optics, metrology data of the fabricated surfaces have to be integrated into the optical model. The focus of this article is on design for manufacturability of freeform optics with integrated alignment structures and on tolerance analysis of the optical subsystem based on the measured surface data of manufactured optical freeform components with respect to assembly and manufacturing tolerances. This approach will be reported here using an ophthalmological system as an example.
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ingo Sieber, Ingo Sieber, Thomas Martin, Thomas Martin, Allen Yi, Allen Yi, Likai Li, Likai Li, Olaf Rübenach, Olaf Rübenach, } "Optical design and tolerancing of an ophthalmological system", Proc. SPIE 9195, Optical System Alignment, Tolerancing, and Verification VIII, 919504 (8 September 2014); doi: 10.1117/12.2060643; https://doi.org/10.1117/12.2060643
PROCEEDINGS
10 PAGES


SHARE
RELATED CONTENT

Larger format freeform fabrication and metrology
Proceedings of SPIE (June 15 2018)
Grinding and polishing of conformal windows and domes
Proceedings of SPIE (May 03 2017)
Semi-Automatic Modulation Transfer Function (MTF) Tolerancing
Proceedings of SPIE (November 29 1979)
Fisheye projection lens for large-format film
Proceedings of SPIE (November 25 1993)
Analysis On Economic Benefit Of Optical System Design
Proceedings of SPIE (January 01 1987)

Back to Top