5 September 2014 Control of a 45-cm long x-ray deformable mirror with either external or internal metrology
Author Affiliations +
Abstract
Our 45-cm long x-ray deformable mirror has 45 actuators along the tangential axis, along with one strain gauge per actuator and eight temperature sensors. We discuss the detailed calibration of the mirror's figure response to voltage (fourth-order) and the strain gauges' response to figure changes (linear). The mirror's cylinder shape changes with temperature, which can be tracked with the temperature sensors. We present initial results of measuring figure change with the strain gauges, which works very well for large changes (> 10 nm peak-to- valley), but is noisy with a single strain reading for small changes (5 nm peak-to-valley).
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Lisa A. Poyneer, Lisa A. Poyneer, Tommaso Pardini, Tommaso Pardini, Thomas McCarville, Thomas McCarville, David Palmer, David Palmer, Audrey Brooks, Audrey Brooks, "Control of a 45-cm long x-ray deformable mirror with either external or internal metrology", Proc. SPIE 9208, Adaptive X-Ray Optics III, 92080F (5 September 2014); doi: 10.1117/12.2062072; https://doi.org/10.1117/12.2062072