5 September 2014 Optimization of <= 200μm pitch CZT detectors for future high-resolution x-ray instrumentation in astrophysics
Author Affiliations +
Abstract
Cadmium Zinc Telluride and Cadmium Telluride are the detector materials of choice for the detection of X-rays in the X-ray energy band E ≥ 5 keV with excellent spatial and spectral resolution and without cryogenic cooling. Owing to recent breakthroughs in grazing incidence mirror technology, next-generation hard X-ray telescopes will achieve angular resolution between 5 and 10 arc seconds - about an order of magnitude better than that of the NuSTAR hard X-ray telescope. As a consequence, the next generation of X-ray telescopes will require pixelated X-ray detectors with pixels on a grid with a lattice constant of ≤ 250 μm. Additional detector requirements include a low energy threshold of less than 5 keV and an energy resolution of less than one keV. The science drivers for a high angular-resolution X-ray mission include studies and measurements of black hole spins, the cosmic evolution of super-massive black holes, active galactic nuclei feedback, and the behaviour of matter at very high densities. In this contribution, we report on our RandD studies with the goal to optimise small-pixel Cadmium Zinc Telluride and Cadmium Telluride detectors.
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Anna Zajczyk, Anna Zajczyk, Marie Draper, Marie Draper, Paul Dowkontt, Paul Dowkontt, Qingzhen Guo, Qingzhen Guo, Fabian Kislat, Fabian Kislat, Henric Krawczynski, Henric Krawczynski, Gianluigi De Geronimo, Gianluigi De Geronimo, Shaorui Li, Shaorui Li, Matthias Beilicke, Matthias Beilicke, } "Optimization of <= 200μm pitch CZT detectors for future high-resolution x-ray instrumentation in astrophysics", Proc. SPIE 9213, Hard X-Ray, Gamma-Ray, and Neutron Detector Physics XVI, 921308 (5 September 2014); doi: 10.1117/12.2062372; https://doi.org/10.1117/12.2062372
PROCEEDINGS
10 PAGES


SHARE
RELATED CONTENT

Simulation of signal induction in the Caliste-SO detector
Proceedings of SPIE (September 11 2015)
Lead iodide films for x-ray imaging
Proceedings of SPIE (May 02 1997)
Silicon drift chamber with extended energy range
Proceedings of SPIE (December 13 2000)
Lead iodide crystals for use in gamma-ray detection
Proceedings of SPIE (December 22 1992)
ZnCdSeTe radiation detectors
Proceedings of SPIE (October 13 2006)

Back to Top