Abstract
Optical coherence tomography (OCT) has been widely employed as non-invasive 3D imaging diagnostic instrument, particularly in the field of ophthalmology. Although OCT has been approved for use in clinic in USA, Europe and Asia, international standardization of this technology is still in progress. Validation of OCT imaging capabilities is considered extremely important to ensure its effective use in clinical diagnoses. Phantom with appropriate test targets can assist evaluate and calibrate imaging performance of OCT at both installation and throughout lifetime of the instrument. In this paper, we design and fabricate a physical model eye with 3D resolution test targets to characterize OCT imaging performance. The model eye was fabricated with transparent resin to simulate realistic ophthalmic testing environment, and most key optical elements including cornea, lens and vitreous body were realized. The test targets which mimic USAF 1951 test chart were fabricated on the fundus of the model eye by 3D printing technology. Differing from traditional two dimensional USAF 1951 test chart, a group of patterns which have different thickness in depth were fabricated. By measuring the 3D test targets, axial resolution as well as lateral resolution of an OCT system can be evaluated at the same time with this model eye. To investigate this specialized model eye, it was measured by a scientific spectral domain OCT instrument and a clinical OCT system respectively. The results demonstrate that the model eye with 3D resolution test targets have the potential of qualitatively and quantitatively validating the performance of OCT systems.
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Zhixiong Hu, Zhixiong Hu, Wenli Liu, Wenli Liu, Baoyu Hong, Baoyu Hong, Bingtao Hao, Bingtao Hao, Lele Wang, Lele Wang, Jiao Li, Jiao Li, } "A physical model eye with 3D resolution test targets for optical coherence tomography", Proc. SPIE 9230, Twelfth International Conference on Photonics and Imaging in Biology and Medicine (PIBM 2014), 92301H (17 September 2014); doi: 10.1117/12.2067974; https://doi.org/10.1117/12.2067974
PROCEEDINGS
7 PAGES


SHARE
Back to Top